双机环境下的A5200在线更换硬盘

来源:cu 作者:东方蜘蛛 时间:2007-09-11 点击:
硬件环境:2xE3500+2xA5200
软件环境:Solaris 2.6+Sun Cluster2.2+vxvm3.0

一、故障硬盘更换前系统情况:
 # uname -a

SunOS fsmsdb1 5.6 Generic_105181-29 sun4u sparc SUNW,Ultra-Enterprise


 
 查看cluster状态:
 

# hastat

Getting Information from all the nodes ......
              HIGH AVAILABILITY CONFIGURATION AND STATUS 
              -------------------------------------------

LIST OF NODES CONFIGURED IN <fsms> CLUSTER
      fsmsdb1 fsmsdb2

CURRENT MEMBERS OF THE CLUSTER

     fsmsdb1 is a cluster member

     fsmsdb2 is a cluster member

CONFIGURATION STATE OF THE CLUSTER

     Configuration State on fsmsdb1: Stable

     Configuration State on fsmsdb2: Stable

UPTIME OF NODES IN THE CLUSTER

     uptime of fsmsdb1:          3:29pm  up 456 day(s), 13:03,  1 user,  load average: 0.62, 0.67, 0.71

     uptime of fsmsdb2:          3:28pm  up 429 day(s), 22:22,  0 users,  load average: 0.01, 0.02, 0.03

LOGICAL HOSTS MASTERED BY THE CLUSTER MEMBERS

Logical Hosts Mastered on fsmsdb1:
        fsmsdb
Logical Hosts for which fsmsdb1 is Backup Node:
        None

Logical Hosts Mastered on fsmsdb2:
        None
Logical Hosts for which fsmsdb2 is Backup Node:
        fsmsdb

LOGICAL HOSTS IN MAINTENANCE STATE

     None

STATUS OF PRIVATE NETS IN THE CLUSTER

     Status of Interconnects on fsmsdb1:
        interconnect0: selected
        interconnect1: up
     Status of private nets on fsmsdb1:
        To fsmsdb1 - UP
        To fsmsdb2 - UP

     Status of Interconnects on fsmsdb2:
        interconnect0: selected
        interconnect1: up
     Status of private nets on fsmsdb2:
        To fsmsdb1 - UP
        To fsmsdb2 - UP

STATUS OF PUBLIC NETS IN THE CLUSTER

Status of Public Network On fsmsdb1:

bkggrp  r_adp   status  fo_time live_adp
nafo0   hme1:hme3       OK      NEVER   hme1

Status of Public Network On fsmsdb2:

bkggrp  r_adp   status  fo_time live_adp
nafo0   hme1:hme3       OK      NEVER   hme1

STATUS OF DATA SERVICES RUNNING IN THE CLUSTER

Status Of Registered Data Services
       sybase:                  On
       nfs:                     Off

Status Of Data Services Running On fsmsdb1
       Data Service "sybase":
       Database Status on fsmsdb1:
        SYBASE_BAK - running; 
        smsserver - running; 


Status Of Data Services Running On fsmsdb2
       Data Service "sybase":
       Not being managed on this system

RECENT  ERROR MESSAGES FROM THE CLUSTER

Recent Error Messages on fsmsdb1

Jun 12 03:02:13 fsmsdb1 unix: NFS server backupserver ok
Jun 15 14:57:59 fsmsdb1 su: 'su root' failed for sybase on /dev/pts/0
Jun 15 14:58:08 fsmsdb1 last message repeated 1 time
Jun 26 02:00:10 fsmsdb1 unix: NFS server backupserver not responding still trying
Jun 26 03:23:39 fsmsdb1 unix: NFS server backupserver ok
Jun 29 11:57:08 fsmsdb1 explorer: Explorer started
Jun 29 12:03:42 fsmsdb1 explorer: Explorer finished

Recent Error Messages on fsmsdb2

Jun 29 12:25:19 fsmsdb2 unix: pseudo-device: lockstat0
Jun 29 12:25:19 fsmsdb2 unix: lockstat0 is /pseudo/lockstat@0
Jun 29 12:26:36 fsmsdb2 unix: WARNING: /sbus@2,0/SUNW,socal@d,10000/sf@0,0/ssd@w2200002037c85404,0 (ssd8):^M^M
Jun 29 12:26:36 fsmsdb2 unix:   transport rejected (-2)^M^M
Jun 29 12:26:47 fsmsdb2 unix:   Vendor 'SEAGATE', product 'ST318304FSUN18G', (unknown capacity)^M
Jun 29 12:28:36 fsmsdb2 last message repeated 8 times
Jun 29 12:29:12 fsmsdb2 explorer: Explorer finished



 

# format

Searching for disks...done


AVAILABLE DISK SELECTIONS:
       0. c0t0d0 <drive type unknown>
          /sbus@2,0/SUNW,socal@d,10000/sf@0,0/ssd@w2100002037c85404,0
       1. c0t5d0 <SUN18G cyl 7506 alt 2 hd 19 sec 248>
          /sbus@2,0/SUNW,socal@d,10000/sf@0,0/ssd@w2100002037d80498,0
       2. c0t10d0 <SUN18G cyl 7506 alt 2 hd 19 sec 248>
          /sbus@2,0/SUNW,socal@d,10000/sf@0,0/ssd@w2100002037d803f1,0
       3. c0t16d0 <SUN18G cyl 7506 alt 2 hd 19 sec 248>
          /sbus@2,0/SUNW,socal@d,10000/sf@0,0/ssd@w2100002037c3b5a7,0
       4. c0t19d0 <SUN18G cyl 7506 alt 2 hd 19 sec 248>
          /sbus@2,0/SUNW,socal@d,10000/sf@0,0/ssd@w2100002037c89c7b,0
       5. c0t26d0 <SUN18G cyl 7506 alt 2 hd 19 sec 248>
          /sbus@2,0/SUNW,socal@d,10000/sf@0,0/ssd@w2100002037c3bf4f,0
       6. c2t0d0 <SUN18G cyl 7506 alt 2 hd 19 sec 248>
          /sbus@6,0/SUNW,socal@d,10000/sf@0,0/ssd@w2100002037e493db,0
       7. c2t2d0 <SUN18G cyl 7506 alt 2 hd 19 sec 248>
          /sbus@6,0/SUNW,socal@d,10000/sf@0,0/ssd@w2100002037d89d9a,0
       8. c3t65d0 <SUN18G cyl 7506 alt 2 hd 19 sec 248>
          /sbus@6,0/SUNW,socal@d,10000/sf@1,0/ssd@w2100002037ba26b8,0
       9. c3t69d0 <SUN18G cyl 7506 alt 2 hd 19 sec 248>
          /sbus@6,0/SUNW,socal@d,10000/sf@1,0/ssd@w2100002037d84870,0
      10. c3t74d0 <SUN18G cyl 7506 alt 2 hd 19 sec 248>
          /sbus@6,0/SUNW,socal@d,10000/sf@1,0/ssd@w2100002037c8546b,0
      11. c3t80d0 <SUN18G cyl 7506 alt 2 hd 19 sec 248>
          /sbus@6,0/SUNW,socal@d,10000/sf@1,0/ssd@w2100002037d83bf4,0
      12. c3t84d0 <SUN18G cyl 7506 alt 2 hd 19 sec 248>
          /sbus@6,0/SUNW,socal@d,10000/sf@1,0/ssd@w2100002037d89c41,0
      13. c3t86d0 <SUN18G cyl 7506 alt 2 hd 19 sec 248>
          /sbus@6,0/SUNW,socal@d,10000/sf@1,0/ssd@w2100002037d83b93,0
      14. c3t90d0 <SUN18G cyl 7506 alt 2 hd 19 sec 248>
          /sbus@6,0/SUNW,socal@d,10000/sf@1,0/ssd@w2100002037d8992a,0
Specify disk (enter its number): ^D

 

大家不要以为c0t0d0一定是本地磁盘哦,看仔细喽:mrgreen:

 

# iostat -En

c1t6d0          Soft Errors: 0 Hard Errors: 4 Transport Errors: 0 
Vendor: TOSHIBA  Product: DVD-ROM SD-M1401 Revision: 1007 Serial No: 06/22/00 
RPM: 0 Heads: 0 Size: 18446744073.71GB <-8589934591 bytes>
Media Error: 0 Device Not Ready: 3 No Device: 1 Recoverable: 0 
Illegal Request: 0 Predictive Failure Analysis: 0 
c2t2d0          Soft Errors: 0 Hard Errors: 0 Transport Errors: 0 
Vendor: SEAGATE  Product: ST318304FSUN18G  Revision: 042D Serial No: 0101L08R9T 
RPM: 7200 Heads: 19 Size: 18.11GB <18110967808 bytes>
Media Error: 0 Device Not Ready: 0 No Device: 0 Recoverable: 0 
Illegal Request: 0 Predictive Failure Analysis: 0 
c2t0d0          Soft Errors: 0 Hard Errors: 0 Transport Errors: 0 
Vendor: SEAGATE  Product: ST318304FSUN18G  Revision: 042D Serial No: 0108L0AG1B 
RPM: 7200 Heads: 19 Size: 18.11GB <18110967808 bytes>
Media Error: 0 Device Not Ready: 0 No Device: 0 Recoverable: 0 
Illegal Request: 0 Predictive Failure Analysis: 0 
c0t10d0         Soft Errors: 0 Hard Errors: 1 Transport Errors: 0 
Vendor: SEAGATE  Product: ST318304FSUN18G  Revision: 042D Serial No: 0050L07FTE 
RPM: 7200 Heads: 19 Size: 18.11GB <18110967808 bytes>
Media Error: 0 Device Not Ready: 0 No Device: 1 Recoverable: 0 
Illegal Request: 0 Predictive Failure Analysis: 0 
c0t26d0         Soft Errors: 0 Hard Errors: 1 Transport Errors: 0 
Vendor: SEAGATE  Product: ST318304FSUN18G  Revision: 0726 Serial No: 0044L069NG 
RPM: 7200 Heads: 19 Size: 18.11GB <18110967808 bytes>
Media Error: 0 Device Not Ready: 0 No Device: 1 Recoverable: 0 
Illegal Request: 0 Predictive Failure Analysis: 0 
c0t5d0          Soft Errors: 0 Hard Errors: 1 Transport Errors: 0 
Vendor: SEAGATE  Product: ST318304FSUN18G  Revision: 042D Serial No: 0050L080EX 
RPM: 7200 Heads: 19 Size: 18.11GB <18110967808 bytes>
Media Error: 0 Device Not Ready: 0 No Device: 1 Recoverable: 0 
Illegal Request: 0 Predictive Failure Analysis: 0 
c0t19d0         Soft Errors: 0 Hard Errors: 1 Transport Errors: 0 
Vendor: SEAGATE  Product: ST318304FSUN18G  Revision: 0726 Serial No: 0047L07HMS 
RPM: 7200 Heads: 19 Size: 18.11GB <18110967808 bytes>
Media Error: 0 Device Not Ready: 0 No Device: 1 Recoverable: 0 
Illegal Request: 0 Predictive Failure Analysis: 0 
c0t16d0         Soft Errors: 0 Hard Errors: 1 Transport Errors: 0 
Vendor: SEAGATE  Product: ST318304FSUN18G  Revision: 0726 Serial No: 0044L062MP 
RPM: 7200 Heads: 19 Size: 18.11GB <18110967808 bytes>
Media Error: 0 Device Not Ready: 0 No Device: 1 Recoverable: 0 
Illegal Request: 0 Predictive Failure Analysis: 0 
c0t0d0          Soft Errors: 0 Hard Errors: 0 Transport Errors: 34 
Vendor: SEAGATE  Product: ST318304FSUN18G  Revision: 042D Serial No: 0046L06SNX 
RPM: 7200 Heads: 19 Size: 18.11GB <18110967808 bytes>
Media Error: 0 Device Not Ready: 0 No Device: 0 Recoverable: 0 
Illegal Request: 0 Predictive Failure Analysis: 0 
c3t69d0         Soft Errors: 0 Hard Errors: 0 Transport Errors: 0 
Vendor: SEAGATE  Product: ST318304FSUN18G  Revision: 042D Serial No: 0050L08BYB 
RPM: 7200 Heads: 19 Size: 18.11GB <18110967808 bytes>
Media Error: 0 Device Not Ready: 0 No Device: 0 Recoverable: 0 
Illegal Request: 0 Predictive Failure Analysis: 0 
c3t84d0         Soft Errors: 0 Hard Errors: 0 Transport Errors: 0 
Vendor: SEAGATE  Product: ST318304FSUN18G  Revision: 042D Serial No: 0101L08S00 
RPM: 7200 Heads: 19 Size: 18.11GB <18110967808 bytes>
Media Error: 0 Device Not Ready: 0 No Device: 0 Recoverable: 0 
Illegal Request: 0 Predictive Failure Analysis: 0 
c3t90d0         Soft Errors: 0 Hard Errors: 0 Transport Errors: 0 
Vendor: SEAGATE  Product: ST318304FSUN18G  Revision: 042D Serial No: 0101L08R9D 
RPM: 7200 Heads: 19 Size: 18.11GB <18110967808 bytes>
Media Error: 0 Device Not Ready: 0 No Device: 0 Recoverable: 0 
Illegal Request: 0 Predictive Failure Analysis: 0 
c3t86d0         Soft Errors: 0 Hard Errors: 0 Transport Errors: 0 
Vendor: SEAGATE  Product: ST318304FSUN18G  Revision: 042D Serial No: 0050L08ETM 
RPM: 7200 Heads: 19 Size: 18.11GB <18110967808 bytes>
Media Error: 0 Device Not Ready: 0 No Device: 0 Recoverable: 0 
Illegal Request: 0 Predictive Failure Analysis: 0 
c3t80d0         Soft Errors: 0 Hard Errors: 0 Transport Errors: 0 
Vendor: SEAGATE  Product: ST318304FSUN18G  Revision: 042D Serial No: 0050L08EEY 
RPM: 7200 Heads: 19 Size: 18.11GB <18110967808 bytes>
Media Error: 0 Device Not Ready: 0 No Device: 0 Recoverable: 0 
Illegal Request: 0 Predictive Failure Analysis: 0 
c3t74d0         Soft Errors: 0 Hard Errors: 0 Transport Errors: 0 
Vendor: SEAGATE  Product: ST318304FSUN18G  Revision: 042D Serial No: 0046L06PDB 
RPM: 7200 Heads: 19 Size: 18.11GB <18110967808 bytes>
Media Error: 0 Device Not Ready: 0 No Device: 0 Recoverable: 0 
Illegal Request: 0 Predictive Failure Analysis: 0 
c3t65d0         Soft Errors: 0 Hard Errors: 0 Transport Errors: 0 
Vendor: SEAGATE  Product: ST318304FSUN18G  Revision: 0726 Serial No: 0131L0AQ60 
RPM: 7200 Heads: 19 Size: 18.11GB <18110967808 bytes>
Media Error: 0 Device Not Ready: 0 No Device: 0 Recoverable: 0 
Illegal Request: 0 Predictive Failure Analysis: 0 
rmt/0           Soft Errors: 578 Hard Errors: 20 Transport Errors: 0 
Vendor: HP       Product: C1537A           Revision: L706 Serial No:   62 



查看Quorum device磁盘情况,如果坏的磁盘刚好是Quorum device磁盘,需要先行重新指定一块新的Quorum device磁盘,而且需要在两台主机都执行!
 

# scconf fsms -p

Checking node status...
Current Configuration for Cluster fsms

  Hosts in cluster:
        fsmsdb1 fsmsdb2  

  Private Network Interfaces for
        fsmsdb1:        hme0 hme2
        fsmsdb2:        hme0 hme2

  Quorum Device Information
Quorum device for hosts fsmsdb1 and fsmsdb2: 0046L06SNX     //通过format和iostat命令可以看出坏的磁盘刚好是Quorum device磁盘

  Logical Host Timeout Value :
        Step10            :720
        Step11            :720
        Logical Host              :180

Logical Host    : fsmsdb

        Node List       : fsmsdb1 fsmsdb2
        Disk Groups     : fsmsdg
        Logical Address : fsmsdb
                Logical Interface       : 1
                Network Interface       : hme1 (fsmsdb1) hme1 (fsmsdb2) 

        Automatic Switchover    : no


 
 

# vxdisk list

DEVICE       TYPE      DISK         GROUP        STATUS
c0t0d0s2     sliced    -            -            error
c0t5d0s2     sliced    dm_c0t5d0    fsmsdg       online
c0t10d0s2    sliced    dm_c0t10d0   fsmsdg       online
c0t16d0s2    sliced    dm_c0t16d0   fsmsdg       online
c0t19d0s2    sliced    dm_c0t19d0   fsmsdg       online
c0t26d0s2    sliced    -            -            error
c2t0d0s2     sliced    -            -            error
c2t0d0s7     simple    c2t0d0s7     rootdg       online
c2t2d0s2     sliced    -            -            error
c3t65d0s2    sliced    dm_c3t65d0   fsmsdg       online
c3t69d0s2    sliced    dm_c3t69d0   fsmsdg       online
c3t74d0s2    sliced    dm_c3t74d0   fsmsdg       online
c3t80d0s2    sliced    dm_c3t80d0   fsmsdg       online
c3t84d0s2    sliced    dm_c3t84d0   fsmsdg       online
c3t86d0s2    sliced    -            -            error
c3t90d0s2    sliced    -            -            error
-            -         dm_c0t0d0    fsmsdg       failed was:c0t0d0s2



 # vxprint -ht

Disk group: rootdg

DG NAME         NCONFIG      NLOG     MINORS   GROUP-ID
DM NAME         DEVICE       TYPE     PRIVLEN  PUBLEN   STATE
V  NAME         USETYPE      KSTATE   STATE    LENGTH   READPOL   PREFPLEX
PL NAME         VOLUME       KSTATE   STATE    LENGTH   LAYOUT    NCOL/WID MODE
SD NAME         PLEX         DISK     DISKOFFS LENGTH   [COL/]OFF DEVICE   MODE
SV NAME         PLEX         VOLNAME  NVOLLAYR LENGTH   [COL/]OFF AM/NM    MODE

dg rootdg       default      default  0        993346192.1026.fsmsdb1

dm c2t0d0s7     c2t0d0s7     simple   1024     74367    -

Disk group: fsmsdg

DG NAME         NCONFIG      NLOG     MINORS   GROUP-ID
DM NAME         DEVICE       TYPE     PRIVLEN  PUBLEN   STATE
V  NAME         USETYPE      KSTATE   STATE    LENGTH   READPOL   PREFPLEX
PL NAME         VOLUME       KSTATE   STATE    LENGTH   LAYOUT    NCOL/WID MODE
SD NAME         PLEX         DISK     DISKOFFS LENGTH   [COL/]OFF DEVICE   MODE
SV NAME         PLEX         VOLNAME  NVOLLAYR LENGTH   [COL/]OFF AM/NM    MODE

dg fsmsdg       default      default  51000    989998066.1084.fsmsdb1

dm dm_c0t0d0    -            -        -        -        NODEVICE
dm dm_c0t5d0    c0t5d0s2     sliced   4711     35363560 -
dm dm_c0t10d0   c0t10d0s2    sliced   4711     35363560 -
dm dm_c0t16d0   c0t16d0s2    sliced   4711     35363560 -
dm dm_c0t19d0   c0t19d0s2    sliced   4711     35363560 -
dm dm_c3t65d0   c3t65d0s2    sliced   4711     35363560 -
dm dm_c3t69d0   c3t69d0s2    sliced   4711     35363560 -
dm dm_c3t74d0   c3t74d0s2    sliced   4711     35363560 -
dm dm_c3t80d0   c3t80d0s2    sliced   4711     35363560 -
dm dm_c3t84d0   c3t84d0s2    sliced   4711     35363560 -

。。。
v  lv_fsmsdb4   gen          ENABLED  ACTIVE   8388608  SELECT    -
pl lv_fsmsdb4-01 lv_fsmsdb4  DISABLED NODEVICE 8392072  CONCAT    -        RW
sd dm_c0t0d0-06 lv_fsmsdb4-01 dm_c0t0d0 25694536 8392072 0        -        RLOC
pl lv_fsmsdb4-02 lv_fsmsdb4  ENABLED  ACTIVE   8392072  CONCAT    -        RW
sd dm_c0t10d0-05 lv_fsmsdb4-02 dm_c0t10d0 33568288 1795272 0      c0t10d0  ENA
sd dm_c0t16d0-05 lv_fsmsdb4-02 dm_c0t16d0 33568288 1795272 1795272 c0t16d0 ENA
sd dm_c3t69d0-05 lv_fsmsdb4-02 dm_c3t69d0 33568288 1795272 3590544 c3t69d0 ENA
sd dm_c0t5d0-07 lv_fsmsdb4-02 dm_c0t5d0 33883992 212040 5385816   c0t5d0   ENA
sd dm_c3t65d0-04 lv_fsmsdb4-02 dm_c3t65d0 16788856 1583232 5597856 c3t65d0 ENA
sd dm_c3t84d0-05 lv_fsmsdb4-02 dm_c3t84d0 33568288 1210984 7181088 c3t84d0 ENA
。。。


还好受到影响的就一个卷,而且还作了mirror,所以也就不贴其他卷出来显眼了!

 # luxadm probe

Found Enclosure(s):
SENA               Name:A1C0   Node WWN:50800200000ea490   
  Logical Path:/dev/es/ses0
  Logical Path:/dev/es/ses1
SENA               Name:A2C3   Node WWN:50800200000ead38   
  Logical Path:/dev/es/ses2
  Logical Path:/dev/es/ses3

Found Fibre Channel device(s):
  Node WWN:2000002037d89d9a  Device Type:Disk device
    Logical Path:/dev/rdsk/c2t2d0s2
  Node WWN:2000002037e493db  Device Type:Disk device
    Logical Path:/dev/rdsk/c2t0d0s2
 
 # luxadm display 50800200000ea490

                                   SENA            
                                 DISK STATUS 
SLOT   FRONT DISKS       (Node WWN)          REAR DISKS        (Node WWN)
0      On (Bypassed:AB)                      On (O.K.)         2000002037c3b5a7
1      Not Installed                         Not Installed                     
2      Not Installed                         Not Installed                     
3      Not Installed                         On (O.K.)         2000002037c89c7b
4      Not Installed                         Not Installed                     
5      On (O.K.)         2000002037d80498    Not Installed                     
6      Not Installed                         On (O.K.)         2000002037c54d3d                  
7      Not Installed                         Not Installed                     
8      Not Installed                         Not Installed                     
9      Not Installed                         Not Installed                     
10     On (O.K.)         2000002037d803f1    On (O.K.)         2000002037c3bf4f
                                SUBSYSTEM STATUS
FW Revision:1.09   Box ID:0   Node WWN:50800200000ea490   Enclosure Name:A1C0
Power Supplies (0,2 in front, 1 in rear)
        0 O.K.(rev.-02) 1 O.K.(rev.-02) 2 O.K.(rev.-02)
Fans (0 in front, 1 in rear)
        0 O.K.(rev.-04) 1 O.K.(rev.-00)
ESI Interface board(IB) (A top, B bottom)
        A: O.K.(rev.-04)
                GBIC module (1 on left, 0 on right in IB)
                0 O.K.(mod.-05)
                1 Not Installed
        B: O.K.(rev.-04)
                GBIC module (1 on left, 0 on right in IB)
                0 O.K.(mod.-05)
                1 Not Installed
Disk backplane (0 in front, 1 in rear)
        Front Backplane: O.K.(rev.-04)
          Temperature sensors (on front backplane)
          0:36篊 1:36篊 2:34篊 3:34篊 4:34篊 5:36篊 
          6:36篊 7:34篊 8:36篊 9:36篊 10:36篊  (All temperatures are NORMAL.)
        Rear Backplane:  O.K.(rev.-04)
          Temperature sensors (on rear backplane)
          0:36篊 1:36篊 2:36篊 3:36篊 4:36篊 5:34篊 
          6:36篊 7:34篊 8:34篊 9:34篊 10:34篊  (All temperatures are NORMAL.)
Interconnect assembly
        O.K.(rev.-02)
Loop  configuration
        Loop A is configured as a single loop.
        Loop B is configured as a single loop.
Language        USA English   

  

通过上面命令可以看到前面板0号磁盘故障,这个柜子的名字叫A1C0。

 # luxadm display 50800200000ead38


                                   SENA            
                                 DISK STATUS 
SLOT   FRONT DISKS       (Node WWN)          REAR DISKS        (Node WWN)
0      Not Installed                         On (O.K.)         2000002037d83bf4
1      On (O.K.)         2000002037ba26b8    Not Installed                     
2      Not Installed                         Not Installed                     
3      Not Installed                         Not Installed                     
4      Not Installed                         On (O.K.)         2000002037d89c41
5      On (O.K.)         2000002037d84870    Not Installed                     
6      Not Installed                         On (O.K.)         2000002037d83b93
7      Not Installed                         Not Installed                     
8      Not Installed                         Not Installed                     
9      Not Installed                         Not Installed                     
10     On (O.K.)         2000002037c8546b    On (O.K.)         2000002037d8992a
                                SUBSYSTEM STATUS
FW Revision:1.09   Box ID:2   Node WWN:50800200000ead38   Enclosure Name:A2C3
Power Supplies (0,2 in front, 1 in rear)
        0 O.K.(rev.-02) 1 O.K.(rev.-02) 2 O.K.(rev.-02)
Fans (0 in front, 1 in rear)
        0 O.K.(rev.-04) 1 O.K.(rev.-00)
ESI Interface board(IB) (A top, B bottom)
        A: O.K.(rev.-04)
                GBIC module (1 on left, 0 on right in IB)
                0 O.K.(mod.-05)
                1 Not Installed
        B: O.K.(rev.-04)
                GBIC module (1 on left, 0 on right in IB)
                0 O.K.(mod.-05)
                1 Not Installed
Disk backplane (0 in front, 1 in rear)
        Front Backplane: O.K.(rev.-04)
          Temperature sensors (on front backplane)
          0:36篊 1:36篊 2:36篊 3:36篊 4:34篊 5:36篊 
          6:36篊 7:34篊 8:34篊 9:36篊 10:36篊  (All temperatures are NORMAL.)
        Rear Backplane:  O.K.(rev.-04)
          Temperature sensors (on rear backplane)
          0:37篊 1:37篊 2:36篊 3:36篊 4:36篊 5:36篊 
          6:37篊 7:36篊 8:36篊 9:36篊 10:36篊  (All temperatures are NORMAL.)
Interconnect assembly
        O.K.(rev.-02)
Loop  configuration
        Loop A is configured as a single loop.
        Loop B is configured as a single loop.
Language        USA English     


第二个A5200的状态正常。

[size=2]二、更换故障硬盘[/size]

1.重新指定一个新的Quorum device

 # scconf fsms -q fsmsdb1 fsmsdb2

Checking node status...
Checking host fsmsdb2 ...fsmsdb2 is alive

Getting device information for hosts fsmsdb1 and fsmsdb2
This may take a few seconds to a few minutes...done
Select quorum device for fsmsdb1 and fsmsdb2.
Type the number corresponding to the desired selection.
For example: 1
 1) DISK:c0t10d0s2:0050L07FTE
 2) DISK:c0t16d0s2:0044L062MP
 3) DISK:c0t19d0s2:0047L07HMS
 4) DISK:c0t26d0s2:0044L069NG
 5) DISK:c0t5d0s2:0050L080EX
 6) DISK:c3t65d0s2:0131L0AQ60
 7) DISK:c3t69d0s2:0050L08BYB
 8) DISK:c3t74d0s2:0046L06PDB
 9) DISK:c3t80d0s2:0050L08EEY
10) DISK:c3t84d0s2:0101L08S00
11) DISK:c3t86d0s2:0050L08ETM
12) DISK:c3t90d0s2:0101L08R9D
Quorum device: 1
Disk c0t10d0s2 with serial id 0050L07FTE has been chosen
as the quorum device.


从上面信息可以看到Quorum device磁盘已经在这里看到不了!

查看Quorum device是否已经被更新:

 # scconf fsms -p

Checking node status...
Current Configuration for Cluster fsms

  Hosts in cluster:
        fsmsdb1 fsmsdb2  

  Private Network Interfaces for
        fsmsdb1:        hme0 hme2
        fsmsdb2:        hme0 hme2

  Quorum Device Information
Quorum device for hosts fsmsdb1 and fsmsdb2: 0050L07FTE

  Logical Host Timeout Value :
        Step10            :720
        Step11            :720
        Logical Host              :180

Logical Host    : fsmsdb

        Node List       : fsmsdb1 fsmsdb2
        Disk Groups     : fsmsdg
        Logical Address : fsmsdb
                Logical Interface       : 1
                Network Interface       : hme1 (fsmsdb1) hme1 (fsmsdb2) 

        Automatic Switchover    : no



登录到node2主机更新Quorum device: 

 # rlogin fsmsdb2

Last login: Fri Jun 29 14:18:26 from fsmsdb1
Sun Microsystems Inc.   SunOS 5.6       Generic August 1997
 # scconf fsms -p
Checking node status...
Current Configuration for Cluster fsms

  Hosts in cluster:
        fsmsdb1 fsmsdb2  

  Private Network Interfaces for
        fsmsdb1:        hme0 hme2
        fsmsdb2:        hme0 hme2

  Quorum Device Information
Quorum device for hosts fsmsdb1 and fsmsdb2: 0046L06SNX

  Logical Host Timeout Value :
        Step10            :720
        Step11            :720
        Logical Host              :180

Logical Host    : fsmsdb

        Node List       : fsmsdb1 fsmsdb2
        Disk Groups     : fsmsdg
        Logical Address : fsmsdb
                Logical Interface       : 1
                Network Interface       : hme1 (fsmsdb1) hme1 (fsmsdb2) 

        Automatic Switchover    : no

 # scconf fsms -q fsmsdb1 fsmsdb2
Checking node status...
Checking host fsmsdb1 ...
fsmsdb1 is alive

Getting device information for hosts fsmsdb1 and fsmsdb2
This may take a few seconds to a few minutes...done
Select quorum device for fsmsdb1 and fsmsdb2.
Type the number corresponding to the desired selection.
For example: 1
 1) DISK:c0t10d0s2:0050L07FTE
 2) DISK:c0t16d0s2:0044L062MP
 3) DISK:c0t19d0s2:0047L07HMS
 4) DISK:c0t26d0s2:0044L069NG
 5) DISK:c0t5d0s2:0050L080EX
 6) DISK:c3t65d0s2:0131L0AQ60
 7) DISK:c3t69d0s2:0050L08BYB
 8) DISK:c3t74d0s2:0046L06PDB
 9) DISK:c3t80d0s2:0050L08EEY
10) DISK:c3t84d0s2:0101L08S00
11) DISK:c3t86d0s2:0050L08ETM
12) DISK:c3t90d0s2:0101L08R9D
Quorum device: 1
Disk c0t10d0s2 with serial id 0050L07FTE has been chosen
as the quorum device.
 # scconf fsms -p
Checking node status...
Current Configuration for Cluster fsms

  Hosts in cluster:
        fsmsdb1 fsmsdb2  

  Private Network Interfaces for
        fsmsdb1:        hme0 hme2
        fsmsdb2:        hme0 hme2

  Quorum Device Information
Quorum device for hosts fsmsdb1 and fsmsdb2: 0050L07FTE

  Logical Host Timeout Value :
        Step10            :720
        Step11            :720
        Logical Host              :180

Logical Host    : fsmsdb

        Node List       : fsmsdb1 fsmsdb2
        Disk Groups     : fsmsdg
        Logical Address : fsmsdb
                Logical Interface       : 1
                Network Interface       : hme1 (fsmsdb1) hme1 (fsmsdb2) 

        Automatic Switchover    : no



2.使用vxdiskadm命令更换坏盘

 # vxdiskadm


Volume Manager Support Operations
Menu: VolumeManager/Disk

 1      Add or initialize one or more disks
 2      Encapsulate one or more disks
 3      Remove a disk
 4      Remove a disk for replacement
 5      Replace a failed or removed disk
 6      Mirror volumes on a disk
 7      Move volumes from a disk
 8      Enable access to (import) a disk group
 9      Remove access to (deport) a disk group
 10     Enable (online) a disk device
 11     Disable (offline) a disk device
 12     Mark a disk as a spare for a disk group
 13     Turn off the spare flag on a disk
 list   List disk information


 ?      Display help about menu
 ??     Display help about the menuing system
 q      Exit from menus

Select an operation to perform: 4